Equipment

GS / FS / SK

Gas Separators

Gas separators, filter-separators and mesh separators for liquid-droplet and solids removal.

Gas Separators: Gas separator functional diagramVessel boundaryGas withentrained liquidInlet deviceSeparation and misteliminationSeparated gasSeparated liquid

Purpose

Protect compressors, dehydration units, metering and gas consumers from liquid carryover and contamination.

Arrangement and integration

Equipment functional diagram

The diagram identifies the principal process duties, equipment connections and product handover points. Final scope, redundancy and battery limits are established from project data.

GS / FS / SKGas separator functional diagramFunctional diagram
Gas Separators: Gas separator functional diagramVessel boundaryGas withentrained liquidInlet deviceSeparation and misteliminationSeparated gasSeparated liquid
Process mediumGasDrain

The simplified diagram identifies the principal process duties and product handover points. Final equipment scope is established from project data.

Engineering basis

Design parameters

Final ratings, materials and supply scope are established from project-specific operating data.

Servicegas-liquid, oil-gas or three-phase mixture
Phase loadsminimum, normal and maximum rates
Design conditionspressure, temperature, slugging and foaming cases
Performance criteriaspecified liquid, gas and solids carryover limits

Process functions

Principal process duties

  • Bulk liquid knockout
  • Fine-droplet coalescence and removal
  • Solids filtration where required

Typical scope

Main equipment

  • 01

    Main process vessel or package

  • 02

    Skid, supports, platforms and piping

  • 03

    Valves, instrumentation and protection systems

  • 04

    Insulation, heat tracing, shelter and electrical systems as required

Questionnaire

Data required for engineering

Worked examples and vessel-volume fields are retained. Use them as guidance or provide parameters from an existing design.

  1. 01

    Process fluid and physical properties

  2. 02

    Flow, pressure and temperature for all cases

  3. 03

    Required process result and allowable pressure drop

  4. 04

    Materials, climate and installation category

  5. 05

    Dimensional constraints, battery limits and automation requirements

Proposal request

Operating data for a technical and commercial proposal

Attach the completed questionnaire or provide the principal operating data below. Equipment scope, design ratings and battery limits follow engineering review.