Equipment

PPT / PP / PBT

PPT Indirect-Fired Process Heaters

Process heaters using a liquid heat-transfer bath between the burner and process coil.

Packaged field heater; the PPT functional diagram is provided below
Packaged field heater; the PPT functional diagram is provided below

Purpose

Heat process streams to the target temperature considering viscosity, pressure, duty and operating mode.

Arrangement and integration

Equipment functional diagram

The diagram identifies the principal process duties, equipment connections and product handover points. Final scope, redundancy and battery limits are established from project data.

PPT / PP / PBTPPT indirect-fired heater functional diagramFunctional diagram
PPT Indirect-Fired Process Heaters: PPT indirect-fired heater functional diagramHeater boundaryHeat transfer through the intermediate fluidHeat dutyCold productProcess coil inheat-transfer bathHeated productFuel and airBurner assemblyIntermediate-fluidheatingFlue gas
Oil / emulsionFuel gasAuxiliary line

A typical equipment arrangement is shown. Final execution, redundancy and valve scope are established during engineering.

Engineering basis

Design parameters

Final ratings, materials and supply scope are established from project-specific operating data.

Throughput500–500,000 kg/h*
Heat duty0.1–10 MW*
Process inlet / outlet temperature−50 to +50 °C / 0 to +70 °C*
Process pressureup to 20 MPa*
Fuelnatural, associated or LPG fuel gas; diesel, fuel oil or crude oil*
Design lifesteelwork — 20 years; coil and firebox — 10 years*

Process functions

Principal process duties

  • Heat-transfer-fluid heating by the burner
  • Process-fluid heating through a coil
  • Automatic control and safety shutdown

Typical scope

Main equipment

  • 01

    Main process vessel or package

  • 02

    Skid, supports, platforms and piping

  • 03

    Valves, instrumentation and protection systems

  • 04

    Insulation, heat tracing, shelter and electrical systems as required

Questionnaire

Data required for engineering

Worked examples and vessel-volume fields are retained. Use them as guidance or provide parameters from an existing design.

  1. 01

    Process fluid and physical properties

  2. 02

    Flow, pressure and temperature for all cases

  3. 03

    Required process result and allowable pressure drop

  4. 04

    Materials, climate and installation category

  5. 05

    Dimensional constraints, battery limits and automation requirements

Proposal request

Operating data for a technical and commercial proposal

Attach the completed questionnaire or provide the principal operating data below. Equipment scope, design ratings and battery limits follow engineering review.

Email the questionnaire, specification and attachments

Related scope

Equipment in the same category